Data Center Substation, Protection & Automation Engineer
Anthropic · Remote-Friendly, United States · Compute · listed October 30, 2026
The shape of it
Seniority
Senior
Experience asked
10+ years
Where
On site
Stated pay
$320,000 – $405,000 USD
Requirements listed
10
Length
2,791 words
In the posting’s own words
As a Data Center Substation, Protection & Automation Engineer, you'll own the protection and automation architecture across Anthropic's US portfolio — from the utility point of interconnection (POI) through the HV/MV substation, the MV distribution loop, and down into LV switchgear. You'll develop and maintain our protection philosophy and reference relay settings, run and review the short-circuit, coordination, and arc-flash studies that underpin them, design the substation automation and SCADA architecture, and define how relays and meters integrate into the electrical power monitoring system (EPMS) — giving operators real-time visibility and sequence-of-events data when something trips. You'll also be our technical lead on the protection side of utility interconnection — working relay settings, transfer-trip, and ride-through requirements with transmission owners and ISOs/RTOs.
What it asks for · 10
- Have 10+ years of experience in power system protection engineering, substation automation, or substation design for utility, heavy-industrial, or mission-critical facilities
- Hold a bachelor's degree in Electrical Engineering or a closely related field, or have equivalent practical experience; Professional Engineer (PE) licensure is valued but not required
- Have deep, hands-on expertise applying and setting protective relays for transformers, feeders, buses, generators, and switchgear, and are fluent in at least one major relay platform (e.g., SEL, GE Multilin, ABB, Siemens)
- Are fluent in short-circuit, protective-device coordination, and arc-flash analysis and comfortable running or critically reviewing studies in tools such as SKM, ETAP, EasyPower, ASPEN, or CAPE
- Have hands-on experience integrating protective relays into substation automation or SCADA systems using protocols such as DNP3, Modbus, or IEC 61850, and understand RTU/gateway and sequence-of-events architecture
- Have worked on utility interconnection protection — relay settings submittals, transfer-trip or communications-assisted schemes, or point-of-interconnection protection requirements — from either the utility or the customer side
- Can read, interpret, and mark up single-line and three-line diagrams, AC and DC schematics, relay panel drawings, and wiring diagrams with confidence
- Have developed relay test plans and witnessed factory acceptance testing, secondary-injection testing, or field commissioning of protection and control systems
- Are familiar with the codes and standards that govern protection and substation work — such as the IEEE C37 series, IEEE 1584, NFPA 70/70E, and (for utility-connected or bulk-electric-system facilities) NERC PRC reliability standards
- Communicate clearly with both technical peers and non-specialist stakeholders, and are results-oriented, with a bias toward practical solutions and a willingness to pick up work outside your core remit when the team needs it
Also a plus
- HV/MV substation physical design experience — general arrangement, bus configuration, power transformer and HV breaker specification, grounding-grid design per IEEE 80, insulation coordination, and control-building layout
- Experience with protection and control for on-site generation (gas turbines, reciprocating engines, fuel cells) and battery energy storage systems, including anti-islanding, synchronizing, and microgrid transfer schemes
- Background in data center, hyperscaler, or other high-availability electrical distribution, and familiarity with critical-power topologies (2N, N+1, distributed redundant)
- Experience owning NERC PRC compliance evidence for a generation or transmission asset — settings basis documentation, misoperation reporting, and PRC-005 maintenance programs
- Proficiency with vendor relay engineering tools such as SEL AcSELerator, GE EnerVista, ABB PCM600, or Siemens DIGSI, and with IEC 61850 system configuration tools
- Designed IEC 61850 station- or process-bus systems with GOOSE-based protection or interlocking schemes
- Prior work at a utility, relay or switchgear manufacturer, protection-engineering consultancy, or hyperscaler serving large-load interconnections
Degree language
- Hold a bachelor's degree in Electrical Engineering or a closely related field, or have equivalent practical experience; Professional Engineer (PE) licensure is valued but not required
Tools and skills named
Ways of working
- Testing14×
- Technical writing4×
Operations & finance
- Supply chain2×
Words the posting leans on
- protection55×
- relay42×
- substation31×
- design26×
- settings26×
- systems21×
- automation20×
- control17×
- schemes15×
- testing14×
- review13×
- experience12×
- relay settings12×
- utility12×
- electrical11×
- standards11×
Counted from the posting after the mission statement and the legal notices are set aside. The ones near the top are the ones a screener is looking for.
The posting, your resume, and the gaps between them. One click loads all three.
More open at Anthropic
- 3P Revenue Accounting & ReportingSan Francisco, CA | Seattle, WA
- Account Executive, AI NativeNew York City, NY; San Francisco, CA | New York City, NY
- Account Executive - DNBSingapore
- Account Executive, NonprofitSan Francisco, CA | New York City, NY
- Account Executive - Public Sector (ASEAN)Singapore
- Account Executive, StartupsDublin, IE