Data Center Power Generation and Microgrids Engineer
Anthropic · Remote-Friendly, United States · Compute · listed October 30, 2026
The shape of it
Seniority
Senior
Experience asked
10+ years
Where
On site
Stated pay
$320,000 – $405,000 USD
Requirements listed
10
Length
3,271 words
In the posting’s own words
As a Data Center Power Generation & Microgrids Engineer, you'll own the behind-the-meter generation and storage architecture for Anthropic's data center portfolio. That means the on-site generation fleet — reciprocating engine gensets, gas turbines, fuel cells — and the battery energy storage systems that buffer load steps and provide ride-through. It means the microgrid layer that ties them together: islanding and resynchronization, black-start, load-shedding, and generation dispatch. And it means the grid side: interconnection studies and agreements, IEEE 1547/2800 compliance, and power quality at the point of interconnection. You'll also own our temporary- and bridging-generation strategies — the plans that let a site energize and start serving load before permanent utility service is available, and transition cleanly once it is.
What it asks for · 10
- Have 10+ years of engineering experience in power generation, microgrids, battery energy storage, or utility interconnection, with substantial time spent on on-site or distributed generation for mission-critical, data center, or large industrial loads, and deep hands-on delivery experience in at least one of these areas (generation, storage, microgrids, or interconnection)
- Have deep hands-on experience with one or more generation technologies — reciprocating engine gensets (diesel and natural gas), gas turbines, or fuel cells — including sizing, paralleling, fuel systems, and emissions controls
- Understand the thermal generation asset classes — reciprocating engines across the size range (sub-MW through 10–20 MW units), small- and medium-frame combustion turbines, and combined cycles — and how each responds to fast load changes and holds stable islanded operation
- Understand battery energy storage sizing for a defined duty (ride-through, load-step buffering, peak shaving), inverter selection (grid-forming vs. grid-following), UL 9540 listing, UL 9540A test data, and NFPA 855 installation requirements
- Understand microgrid architecture end to end — islanding detection and transition, resynchronization, black-start, load-shedding, and generation dispatch
- Are fluent in interconnection standards and processes — IEEE 1547, IEEE 2800, utility interconnection requirements, and ISO/RTO study and queue processes
- Are comfortable running or critically reviewing power-system studies — load flow, short-circuit, transient stability, and power quality — in tools such as ETAP, SKM, PSS®E, PSCAD, or EasyPower
- Hold a bachelor's degree in Electrical Engineering, Power Engineering, or a closely related field, or have equivalent practical experience; Professional Engineer (PE) licensure is valued but not required
- Have worked directly with generation OEMs, BESS integrators, generation-as-a-service providers, or utilities, and can evaluate equipment and proposals on technical merit rather than datasheet claims
- Communicate clearly with technical peers, utilities, regulators, and non-specialist stakeholders, and are results-oriented with a bias toward practical solutions and a willingness to pick up work outside your core remit when the team needs it
Also a plus
- Designed or delivered battery energy storage systems at MW scale
- Specified or commissioned a microgrid controller for a site that can island and resynchronize
- Taken at least one large load or generation interconnection from application through agreement
- HV/MV substation design experience — main one-line development, equipment specification, grounding, and layout — since on-site generation and storage tie in at the substation and the two scopes are tightly coupled
- A protection-engineering background covering generation and interconnection protection — relay selection and settings, anti-islanding schemes, and coordination between on-site sources and utility protection
- Experience integrating renewable generation (solar PV, wind) with storage into hybrid behind-the-meter plants
- Experience on the technical side of air permitting for stationary generation (e.g., Title V, NSR/PSD, or state equivalents) and emissions-control equipment selection
- Electromagnetic-transient (EMT) modeling experience in PSCAD or EMTP for inverter-based resource and microgrid-transition studies
Degree language
- Hold a bachelor's degree in Electrical Engineering, Power Engineering, or a closely related field, or have equivalent practical experience; Professional Engineer (PE) licensure is valued but not required
Tools and skills named
Ways of working
- Testing5×
- Cross-functional
Models & research
- Machine learning2×
Words the posting leans on
- generation69×
- interconnection36×
- storage28×
- design25×
- load23×
- microgrid23×
- site23×
- power19×
- experience18×
- systems17×
- technical17×
- requirements16×
- utility14×
- controls13×
- studies13×
- nfpa12×
Counted from the posting after the mission statement and the legal notices are set aside. The ones near the top are the ones a screener is looking for.
The posting, your resume, and the gaps between them. One click loads all three.
More open at Anthropic
- 3P Revenue Accounting & ReportingSan Francisco, CA | Seattle, WA
- Account Executive, AI NativeNew York City, NY; San Francisco, CA | New York City, NY
- Account Executive - DNBSingapore
- Account Executive, NonprofitSan Francisco, CA | New York City, NY
- Account Executive - Public Sector (ASEAN)Singapore
- Account Executive, StartupsDublin, IE